How to deal with the external factors of the electronic scale?

Our company makes the following answers according to the customer's external factors of electronic scales:

First of all, it should be based on the principle of first and second. After the electronic scale fails, the influence of external factors should be excluded first. Changes in the external environment can have a direct impact on the weighing of the electronic scale. Changes in power supply, vibration, wind, and lightning can cause the electronic scale to be unstable. Wind and lightning are force majeure, and we can't avoid it. Therefore, we should try to avoid starting in high winds and thunderstorms. At the same time, the lightning protection measures and grounding protection of the electronic scale should be done. For vibration, measures such as cushioning devices, isolation grooves, etc. can be taken to reduce the influence. The power supply is not pure, and the method of separately wiring or adding a parameter regulator for the electronic scale can be adopted.

Case:
Fault phenomenon: Our company has a SCS-2 electronic cylinder scale. The instrument often shows that the value is unstable during work. Irregular changes. And the range of change is very large, it can not be properly weighed. Occasionally, it works fine.

Fault analysis: The displayed value changes from normal to normal. First suspect the power supply and external interference. Use a multimeter to observe the power supply voltage. Sometimes there are sudden fluctuations. Carefully observed at the scene, found an electric crane near the electronic platform. When the crane is working, the scale display is unstable. After the crane is stopped, the electronic platform is also restored to the normal power supply circuit of the electronic scale. It was found that the electronic platform was connected to the crane on the same line, and the crane had great ripple interference to the circuit when it was working.

Troubleshooting: Separate the power supply of the electronic weighbridge from the crane. Introduce a separate power supply for the electronic platform. Troubleshooting.

Electric power source Operating Table , selection of Motor push rod power, high quality and reliability. Electric Surgical Table, 2. Use imported gas spring as the manual power source of the operating table, stable performance. Electric OT Table, 3. Operating table using medical-grade 304 stainless steel, more modern, cleaner and more convenient. Integrated operating table, Electric Surgery Table, 4. High-strength stainless steel bottom cover, compressive ability, anti-corrosion, easy to clean. 5 head and leg plate removable, easy to operate, provide more flexible surgical space. Electric Operation Table, 6. Hand control, and has a key switch to prevent misuse. 7. Operating table base has a fixed or mobile function, mobile and flexible, fixed and reliable. 8. Countertop optional built-in waist bridge, gallbladder, kidney and other operations to provide convenience. Hospital integrated operating table, 9. Optional built-in battery to protect the operating table without interruption. 10. Table optional longitudinal translation, to achieve all-C shooting.


Operating TableImg 6692

3

Electric Operating Table

Electric Operating Table,Electric Hospital Beds,Electric Medical Operating Table,Medical Electric Operating Table

Shandong Kang'erjian Medical Technology Ltd. , https://www.operatingtable.nl